Dimensional Tolerances

Nominal dimensions (mm)

  • B and H: ± 0,5 % with Minimum ± 0,20 mm
  • B and H: ± 0,5 % with maximum ± 0,75 mm

Diametre of Rods and Tubes

D, d (mm)

0 - 10
10 - 20
20 - 50
50 - 100
100 -

 

D

± 0,20
± 0,30
± 0,35
± 0,40
± 0,45

 

d

± 0,20
± 0,30
± 0,35
± 0,40
± 0,45

Wall-thickness of open and closed profiles

Nominal dimensions (mm)

Thickness

0 - 2
2 - 5
5 - 10
10 -

 

 

T1

± 0,15
± 0,20
± 0,35
± 0,45

 

 

T2

± 0,30
± 0,35
± 0,45
± 0,50

Flatness in transverse direction

Tolerance
F < 0,008 X B mm

Size of angle

Tolerance
Y ± 1,5°

Straightness

Tolerance (B and H are overall breadth and height dimensions)

  • D < 0,002 x L2 for sections with B or H < 50 mm
  • D < 0,001 x L2 for sections with B or H ≥ 50 mm and < 100 mm
  • D < 0,0005 x L2 for sections with B or H ≥ 100 mm

Twist

Tolerance

  • V < 1,5° per metre maximum
    for thickness < 5 mm
  • V < 1,0° per metre maximum
    for thickness ≥ 5 mm

Length of cut

L + 20 / - 0 mm

Angularity of cut

V ± 1,5°